วันพฤหัสบดีที่ 22 มกราคม พ.ศ. 2558

Instruction Sheet Hydraulic Hand Pumps

ISPECIFICATIONS: Use this instruction sheet for the following hand pump
models.
Hand Pump Specifications
Model Type Maximum Pressure Oil Volume per Stroke Usable Oil Capacity
(Speed) Rating psi [bar] in3 [cm3] in3 [cm3]
P20 1 2,850 [200] .16 [2.62] 20 [328]
P41 1 10,000 [700] .16 [2.62] 45 [738]
P70 1 10,000 [700] .16 [2.62] 70 [1147]
P71 1 10,000 [700] .19 [3.1] 70 [1147]
Stage 1 Stage 2 Stage 1 Stage 2
P140 2 400 [28] 10,000 [700] 2.8 [45.9] .24 [3.9] 140 [2295]
P140D 2 400 [28] 10,000 [700] 2.8 [45.9] .24 [3.9] 140 [2295]
P22 2 200 [14] 10,000 [700] .23 [3.8] .06 [1] 20 [3.28]
P42 2 200 [14] 10,000 [700] .82 [13.4] .16 [2.6] 45 [738]
P82 2 200 [14] 10,000 [700] .82 [13.4] .16 [2.6] 145 [2377]
P72 2 200 [14] 10,000 [700] .91 [14.9] .19 [3.1] 70 [1147]
P461 2 400 [28] 10,000 [700] 7.7 [126.2] .3 [4.9] 460 [7539]
P461D 2 400 [28] 10,000 [700] 7.7 [126.2] .3 [4.9] 460 [7539]
CAUTION
Always use the handle to carry the pump. Carrying the
pump by the hose may damage the hose and/or the pump.
WARNING
Always check product specifications regarding pressure
ratings, and capacities. The system operating pressure
must not exceed the pressure rating of the lowest rated
component in the system.
WARNING
NEVER set the relief valve to a higher pressure than the
maximum rated pressure of the pump. Higher settings may
result in equipment damage and/or personal injury.
INSTALLATION
Connecting the Pump
1. Thread hose into pump outlet. Use 1/2 wraps of Teflon tape (or suitable
thread sealant) on hose fitting, leaving the first complete thread free of tape
to ensure that tape does not shed into hydraulic system, causing damage.
Trim loose ends.
A Division Of Templeton, Kenly & Co., Inc.
 2. Install a pressure gauge in-line from the pump for added safety and better
control.
3. Connect the hose(s) to your cylinder or tool.
OPERATION
Before Using the Pump
1. Check all system fittings and connections to be sure they are tight and leak free.
CAUTION
1. Close release valve by turning clockwise, as shown in Figure 1.
Figure 1
2. Operate pump handle to deliver hydraulic power to system. Pressure will be
maintained until release valve is opened.
3. Open release valve (turn counter-clockwise) to release pressure, allowing oil
to flow back to the reservoir.